Changes between Version 5 and Version 6 of Research/DesignStudy/Meetings/2019/12-20
- Timestamp:
- Dec 20, 2019, 6:38:53 PM (5 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
Research/DesignStudy/Meetings/2019/12-20
v5 v6 16 16 * Also, debris that comes through the hole will cause contamination within the volume of the lens. 17 17 * Consequence is that capture lens needs to be designed to accept poor vacuum and significant particle contamination. The target vacuum vessel operates around 10^-4^ to 10^-5^ whereas the Gabor lens operates at a couple of orders of magnitude less. 18 * Various mitigations to large hole (8mm hole at 10cm). This could be small-diameter mylar (or other material) window. Have made 50 micron thick 50mm diameter windows that can hold off 1 bar. Even may need to accept a solenoid rather than a Gabor lens.18 * Various mitigations to large hole (8mm hole at 10cm). This could be small-diameter mylar (or other material) window. Have made 50 micron thick 50mm diameter mylar windows that can hold off 1 bar. Even may need to accept a solenoid rather than a Gabor lens. 19 19 * Can calculate what the pressures would be based on a thick plate with a tapered hole. It's not a problem to set up the simulation to look at a number of different lengths and aperture diameters. 20 20 * //OE//: