    1818        * JP: A number of issues in the CDR need correcting:
    19                 * Pg. 8; there should be no specified number of RF cavities. Five is only in the schematic diagram & has no physical basis for being that number.
     19                * Pg. 8; there should be no specified number of RF cavities. There are five only in the schematic diagram, there is no physical basis for that number to be included.
    2020                * Pg. 9; eqn 2.1 units are not correct. The E_I term should be mass, not energy.
    2121                * Pg. 10 (2.2.3 paragraph 2); the β0 equation is wrong, the r.h.s. should be p_0 c/E_0. 
     
    4040                * Pg. 37; table 2.14 should be removed, it's repeating 2.12. The reference to the table on page 36 should be updated to 2.12.
    4141                * Pg. 42 (2.4.5 paragraph 2); equation β=p/E is wrong, should be β=pc/E,
    42                 * Pg. 51 (2.5.4 paragraph 2); the follwoing sentences are not correct & must be removed:
     42                * Pg. 51 (2.5.4 paragraph 2); the following sentences are not correct & must be removed:
    4343{{{
    4444 The design of the FFA magnet requires the kicker magnet to bend the beam by 90◦, such a magnet is feasible is wrong.