| | 15 | * A few minor issues required discussion on the CDR: |
| | 16 | * Eqn 2.17 has a factor ''t'' in it which cannot be correct. Author unknown, JP to read references & correct. |
| | 17 | * Emittance not consistent in table 2.12, WS pointed out that MAD-X assumes constant emittance whereas BDSIM & GPT do not. JM to remove MAD-X emittance value from that table. |
| | 18 | * Font is small on a number of figures. WS can easily replot with larger fonts. JM & KL to send list of figures that need modifying. |
| | 19 | * WS to send JM the updated LhARA schematic diagram with updated caption. |
| | 20 | * WS to add dimensions to the diagram. |
| | 21 | * KL highlighted preferred use of mm & m, and to avoid cm. Text can be changed but modifying figures might be troublesome. Is context specific. |
| 17 | | * |
| | 23 | * WS: no update due to time toward Imperial Lates last week. |
| | 24 | * TJK: plots shown on field leakage (see attached). |
| | 25 | * End leakage small & away from the cavity, not thought to be significant. |
| | 26 | * Field in the aperture/GFR does is larger. JP pointed out that the cores are at the edge of the aperture, not in it. |
| | 27 | * 250mm long cavity included but planned device is 200mm long |
| | 28 | * JP: Presented on chromatic effects in the Stage 1 arc. Slides will be attached. |
| | 29 | * Dispersion calculated to be small. Higher order dispersion is finite & thought may be contributing to the effects MP sees. |
| | 30 | * The impact on the beam size is small but this is noted to be recorded at the arc exit, not the end station (2m downstream). |