Changes between Version 2 and Version 3 of Research/LhARA/RadiationBiology/Meetings/2025-10-30
- Timestamp:
- Oct 30, 2025, 5:00:21 PM (5 days ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
Research/LhARA/RadiationBiology/Meetings/2025-10-30
v2 v3 3 3 **ZOOM:** https://imperial-ac-uk.zoom.us/j/98220889714?pwd=SM90vOF7BKSXoU3mD9q7OwBQo4IVB3.1 4 4 5 == Agenda == 5 Attended: CW, KL, HO, AFr, MH, ND, CD, BT 6 7 == Meeting Notes == 6 8 7 9 1. Minutes and actions: … … 17 19 - **Done** Waiting 18 20 - **RW:** Add lip to RCF holder 19 - ** Stands**21 - **Done** 20 22 - **KL/CD:** Get RCF cut 21 23 - **Done** 22 24 23 25 2. Strathclyde: BT, ED, RW \\ 24 - Laser problem explanation25 - Quad focussing update 26 - Beamline update: 27 - Missing pulses were traced to a failed power supply. New power supply gives an increase in energy. The increase in power was sufficient to move one of the system outside its linear range and compromise operation. There are ND filters in the system to correct for this and once the problem was identified and located, the level of filtering was corrected and the team were able to produce a good focal spot at close on Tuesday. On Wednesday, the quads were placed in the beamline and we saw proton focus. Today (Thursday), the quads were moved as close to the source as possible, and an increase in proton flux was seen. A z-scan has also been performed, waiting for resutls. 26 28 - Dose Rate Update: 27 - Tony results 28 - Calvin Results 29 - [raw-attachment: Dose_Rate_Calc.pptx Slides] 30 - Calvin's sim produced ~1Gy. The RCF dose calculated by Nick peaked at 7Gy in the distribution. Tony produced a number of 2000Gy. Believe this must be a normalisation issue. Possibly a confusion of N vs E compared with dN/dE vs E 31 - Clarify the problem to Tony so that he can calculate a more accurate dose per pulse 32 - Will always have an issue with background subtraction that can cause a large variation in the calculated dose 33 - Could remove some uncertainty by many RCF shots 34 - Clear we need a faster way to calculate dose from the RCF 29 35 30 36 3. Simulation CD, DA, AFr: \\ 31 - Calvin optimisation Results 37 - Results indicated quads are best placed as close to the source as possible and as close to each other as possible. The gold foil should be at the tube entrance, and the cell dish should be as close to the vacuum window as possible. The importance of these reduces in the order of them being stated here. 38 - However, fear with the statistics used in the optimisation causing the noise to dominate and uniformity being lost to noise. 39 - Can improve the sims by reducing the bin sizes. 40 - [raw-attachment: Optimal_gold_setup.pptx Slides] 32 41 - Alfredo simulation results 33 - Replacement for gold foil discussion 42 - Indicated that a run with higher stats still looks uniform 43 - Highlighted an important issue, that in sim we can optimise number of protons against number of bins, there is a real world limit to these values in the number of protons per pulse and the area of a cell nucleus (110um^2). 44 - Calculate the average proton to proton distance in simulation. 34 45 35 46 4. BioPrep EM, JP: \\ 36 - Incubator update 37 - Consumables ordered 38 - Tick off other items on checklist 47 - Tick off items on checklist 48 - Incubator update - Double 49 - Consumables ordered - Waiting for delivery 50 - Waste stream - Sorted 51 - Microscope - camera not needed 52 - Hoods serviced - Check anything else needs doing to them? No 53 - Ice machine - Sorted 39 54 - Plan for staining finalised 40 55 - Marie Boyd update … … 46 61 - Real-time beam diagnostic update 47 62 - Lanex with a hole ready to go 63 - Lanex also placed behind the cell dish 48 64 49 65 6. DoNM 50 - Next Week: 30th Oct66 - Next Week: 13th Nov 51 67 52 68 7. AoB
