= LhARA radiobiology; meeting: 13Nov25; 14:00 BST = **ZOOM:** https://imperial-ac-uk.zoom.us/j/98220889714?pwd=SM90vOF7BKSXoU3mD9q7OwBQo4IVB3.1 Attended: EM, CD, JMcG, DA, TP, ND, MH == Meeting Notes == 1. Minutes and actions: - **CW:** Contact Marie Boyd - **Done** Waiting. Probably worth waiting till we irradiate cells. 2. Strathclyde: BT, ED, RW, CD, TP, EM \\ - RW: Update on laser - Front quad is quite shiny so placed something in front to reduce reflection. - Changed around 5 separate things and now (fingers crossed) do not see the burning... - Ran 20 shots on Tues and Weds and saw no burning - Does mean not sure what caused it and could be any of the 5 things, including front quad being reflective... - CD: Recap of experimental and simulated results - [raw-attachment: Slides] - Nick pointed out there is still a flaw in the comparison based on the number of particles reaching the final dish - Simulations producing similar shapes to experimental results - Based on Highland equation for multiple scattering angle (from Geant4 documentation) predicted the different scattering effects - Mark has offered 2.5um Gold if we wanted to try that? - Cu 10um at furthest distance from second quad seems like a sensible option - If not uniform enough can move it closer - If we move it so the copper is 300mm from second quad then sims predict the dose will drop by 45% and the CV goes down by 6% - Robbie has a spare drive that we could use to play with this without pumping down the vacuum chamber each time - RCF update: Plan to recalibrate - EM update on Birmingham calibration - Calibration Done - [raw-attachment: Slides] - 2023 batch is much preferred due to the framing we see around the edge of the darker batch - If we use the darker batch in the future cut only for the centre to avoid the framing - Calibration was also complete for some of the framed parts of the film to get some values for previously scanned work - Three sheets of the 2023 batch with Emma - I think there is more in SCAPA - Ask Ewan - KL/CD update on 2023 getting cut to 1cmx1cm: - Hopefully done by tomorrow - For future use best to buy a new batch and complete a calibration just before irradiating - Scanner Best Practices: - Place black cardboard around the RCF on the scanner to fix its position - Run 5-10 scans before scanning RCF to allow the scanner lamp to warm up - RCF Dose Calculation: - [raw-attachment: Slides] - Key Conclusions: - Scanner Best Practices: - Place black cardboard around the RCF on the scanner to fix its position - Run 5-10 scans before scanning RCF to allow the scanner lamp to warm up - An x by x median filter kernel should be applied to the dose map before calculating the flatness. Tony uses x=5. - A three channel correction could provide a more accurate dose than using one channel - Variability pixel to pixel? - Comes from the scanner resolution and is not indicative of low stats hitting each cell - 1 Gy means around 70 particles traversing the nucleus 3. BioPrep EM, JP: \\ - EM: Dry run outcome - Staining to be completed on Monday - CW: Marie Boyd update - Wait till we have some cells irradiated - Emma has to be in Oxford on Friday so cells need to be irradiated before then - Possibility of extra days due to laser downtime? - Chat more about this on Monday 4. Simulation CD, DA, AFr: \\ - No update other than sims included above 5. Beam Diagnostics KL, CD: \\ - Real-time beam diagnostic update - Lanex tested in the beamline appears to work - Lanex behind the cell dish 6. DoNM - 27th Nov 7. AoB - Josie viva - Completed it mate ----