18 | | * JP: CDR. Pg 8, five cavities is not correct. Eqn 2.1 units are not correct, should be mass & not energy. Beta0 equation wrong. Gabor lens injector for lens 1 & 2 is downstream, not upstream. Wien filter for velocity selection. Eqn 2.9 should be sigma p, text changed to momentum. Stage 2 operation beam aperture is fine, better reason is emittance issue. Markus ion chamber volume times 10^-8, |
| 18 | * JP: CDR. Pg 8, five cavities is not correct. Eqn 2.1 units are not correct, should be mass & not energy. Beta0 equation wrong. Gabor lens injector for lens 1 & 2 is downstream, not upstream. Wien filter for velocity selection. Eqn 2.9 should be sigma p, text changed to momentum. Stage 2 operation beam aperture is fine, better reason is emittance issue. Markus ion chamber volume times 10^-8, Fig. 21.6 replot with right axis for dispersion. 32. Remove emittance of ϵx,y = 99 m from page 35. 2.14 table to be removed, repaeting 2.12. Stage 2 dose estimation β= p/E, where p and E. The design of the FFA magnet requires the kicker magnet to bend the beam by 90◦, such a magnet is feasible is wrong. |