LhARA radiobiology; meeting: 27Nov25; 14:00 BST
ZOOM: https://imperial-ac-uk.zoom.us/j/98220889714?pwd=SM90vOF7BKSXoU3mD9q7OwBQo4IVB3.1
Attended: EM, JMcG, CW, DA, AFr, TP, AG, MB, MH, JP, RW, CD
Meeting Notes
- Minutes and actions:
- Laser: RW
- RW: Explanation of the laser problem and the fix
- That problem seems permanently fixed.
- RCF: AFR, DA, CD
- Calibration
- Rotation Issue
- Rotating the films in the scanner can cause a ~30% change to the mean dose in a particular case. More generally causes a substantial difference.
- Can combat by rotating the films each time we scan and always selecting the orientation that gives the highest mean pixel count
- Calculating Dose per Shot, Variation and Dose delivered to Cells
- From RCF, average dose per shot of 0.61±0.25Gy (More data to be analysed)
- Hard to spot a variation day to day
- Variation in one showed a change after 8 films had been irradiated. Need to analyse the shots to get a better understanding of what this is
- Robbie's suggestion is a defocussing laser spot effect
- Flatness and Uniformity of Dose
- Average CV: 15.1±2.5%
- Average Flatness in X: 26.4±5.5%
- Average Flatness in Y: 29.6±4.7%
- Beam is too non-uniform still
- Sim comparison
- CV: 17%
- Moving the Copper closer would bring CV down to 9% and the mean dose would also fall by 45%
- Bio: EM, JP
- EM: Summary of Experiment
Dry Run
- Seeding density test
FaDu gave a plating efficiency of 40?%
- Marie Boyd update
- Comet analysis
Alive dead stain can be done after a couple of hours? That depends on the dose received to how to wait
- Collect pellets and do a western blot test for a rough idea
- Could not tell between a 2 and 4Gy
H2X -There is a way to select cells from all the same area. Though there is the issue that there are not enough cells then.
- IF might give an idea of hotspots
- x-ray irradiate with a known dose to do a comparison
- Marie will do a comet assay
- Plan for staining and delivery back to Birmingham
- Move things to Marie's lab
- Can also do some control irradiations at Marie's as well
- From the colonies, no growth in the controls either
- Microscope is not great, so Marie can take their one to SCAPA
- Could be the microscope that means cannot see any cells
- Marie can do the staining check on Friday but will do on Monday
- The cells were dried out by 50%, incubator felt very hot and humid. Put a thermometer in it to check
- Future:
- Current Problems:
- Clear Communication of Requirements
- RCF to Dose Procedure
- Alfredo and Diaza are piecing together a protocol document to standardise how we complete this procedure
- The rotation issue is taken into account
- Diaza in favour of scanning at lower resolution to speed it up
- Uniformity not good enough
- Place the Copper scatterer closer
- Results need to analysed
- Shot-to-shot variation
- Include a piece of RCF in front of the cells (Ideally delaminated but not possible to calibrate before the next visit)
- Need to sim what the LET would be for our energy range into the cells with the RCF in place
- Longer-term investigate an on-beam diagnostic
- Another option is to find a correlation between the RCF mean dose and one of the laser diagnostics that the team already gathers
- Include a piece of RCF in front of the cells (Ideally delaminated but not possible to calibrate before the next visit)
- Discussion of when to use the rollover days
- Plan to use Wednesday, Thursday and Friday next week
- If good, then use the 3 days to do more cell irradiations
- Emma will send the dishes up tomorrow
- If not work on more beam diagnostics and improving it to complete cell irradiations, tackling either uniformity or shot-to-shot variation
- IPAC abstract submission?
- No takers and a belief that we should wait until we have a slam dunk result
- Note: LhARA will have a general submission that will mention PoPLaR
- Book a longer discussion to analyse all the results and define a plan for the future
- Not discussed
- DoNM
- 11th Dec
- AoB
- Congratulations Dr Melia!!!