Changes between Version 1 and Version 2 of Research/LhARA/RadiationBiology/Meetings/2026-10-01
- Timestamp:
- Oct 1, 2026, 3:34:45 PM (4 days ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
Research/LhARA/RadiationBiology/Meetings/2026-10-01
v1 v2 7 7 - Trello: https://trello.com/invite/b/67587c515b0c69656ee78b48/ATTIe86f94b24e3e5884e4cb87e5ed3b89ab64321B83/poplar 8 8 9 == Meeting Agenda == 9 Attended: KL, MH, CW, TP, SdL, PB, RH, RA, FA, CD 10 11 == Meeting Notes == 10 12 11 13 1. Alternate Beamlines 12 14 - ELIMED part of the next ELI submission 13 15 - There appear to be calls for ELIMED every year 16 - 20th October 12:00 (noon) 17 - Unlikely to make this deadline 18 - Cannot make a submission repeating the same missing details 19 - BUT: 20 - **Calvin to share the document** 21 - **Ken and Josie to nudge the bioplan into action** 14 22 15 23 2. BioPrep 16 - Check where the transwells are being delivered to 17 - Alex seen SCAPA? 18 - General Updates 24 - Alex seen SCAPA 25 - Yes and transwells have been agreed to be the best way forward 26 - Transwells 27 - Cost ~£1000 28 - February puts the bio team on a timetable 29 - Need a stronger bio/SCAPA presence at these meetings 30 - **Colin to reach out to Marie** 31 - **Colin to reach out to the SCAPA team to confirm February is our goal** 19 32 20 33 3. Instrumentation 21 34 - RCF 22 - Updates on delaminated EBT4 (Got some from Ben Phoenix?) 35 - Updates on delaminated EBT4 36 - No longer sold unless for 100 boxes or more 37 - Need 35 more boxes to get an order 38 - Mark found a different type of film 39 - Tony has requested a free sample to check it out 40 - Tony has two master's students on cmos and can compare to the new film 23 41 - SciFi 24 42 - Construction pad is built 25 - Fast electrons 26 - Need a better understanding of the electron-to-proton distribution 43 - Appears to be no sensitivity to rotation of the array (as expected) 44 - Thin wall ion chamber 45 - On-line detector uses protons 46 - Thin window (10s of um of Mylar) 47 - Concern is mainly recombination at the time of ionisation because of the intense pulse 48 - Will still see a residual ionisation 49 - Diamond detector 50 - Off-line using the electrons 51 - Need a better understanding of the electrons to understand its feasibility 52 - **Richard to discuss thin wall detectors and diamond detectors at a Tuesday meeting** 53 - Calorimeter 54 - Measure the energy by measuring the temperature change in graphite 55 - Most stable and understood measure of dose 56 - If we had £10K can ask the same company NPL asked to make a transcal detector thin enough for our energies 57 - Sam Flynn's detector that has been discussed before 58 - Longer term benefit is thatthey're known compared with something like air fluoresence which is not as well known 59 - Further discussion: 60 - Need to group these diagnostics into: 61 - In-beam beamline diagnostics 62 - Dosimetry run at the same time as cells. Measuring the dose in the cells. eg ion-acoustic 63 - Measuring the dose of the low-energy beams to establish stability 64 - As always, beamtime available in Birmingham 65 - **Ken, Simon, Calvin and Josie to discuss next week** 27 66 28 67 4. SCAPA 29 68 - Updates 69 - No update 30 70 31 71 5. Review Trello: https://trello.com/invite/b/67587c515b0c69656ee78b48/ATTIe86f94b24e3e5884e4cb87e5ed3b89ab64321B83/poplar … … 35 75 36 76 7. AoB 37 77 - Funds 78 - Have £5k 79 - Ken meeting this afternoon to discuss £14k Imperial money 38 80 39 81 === Summary of actions required ===
