Smart phantom meeting 21st September 2018
Meeting details
15:00 Blackett Room 1105
Phone details:
UK: 08082 380274 Austria: 0800 006612 PIN: 5904750902
Agenda:
- Contribution to non-clinical research programme; discussion: All
- Smart phantom: concept and discussion: AK/All
- Towards a concept and specification for end station; discussion: All
Notes:
Present: SG, AK, KL, VB, HT
- Contribution to non-clinical research programme; discussion: All
- Smart phantom: concept and discussion: AK/All
- We agreed that the instrumented (smart) phantom that can deliver a measurement of LET/dose shot-by-shot was a valuable contribution. So, we pursue the development of the sci-fi detector interleaved with the sample flasks.
- AK presented the slides. Points noted:
- Two proton energy ranges to be considered: 130--180 MeV; 60--120MeV. Proton energy spread ~1.5%.
- Dose rates over flask surface: 0.5, 1, 2, 4 and 6 Gy. Delivered in spots of dimension 0.3x0.3 cm2. Each 'spot' has a fraction of the total dose, so that the dose to the flask adds up to the numbers given above.
- Flask sizes: 3x1.5 cm2 and 8x5 cm2.
- SmartPhanton or iPhantom ... we discussed. Eventually, VB observed that iPhantom sounded too much like EyePhanton. So, we've adopted SmartPhantom.
- Smart phantom: concept and discussion: AK/All
- Towards a concept and specification for end station; discussion: All
- Working towards proposal for 'LARA' or a part of LARA on the timescale of Dec/Jan.
- We agreed to work on a specification/simulation of the endstation since this was a critical piece of the specification for LARA.
- HT would work with SG and be the interface to Impeiral for both the SmartPhanton and the LARA endstation design.
Last modified
6 years ago
Last modified on Sep 25, 2018, 12:21:13 PM
Attachments (1)
- Simulations.pdf (129.0 KB ) - added by 6 years ago.
Download all attachments as: .zip
Note:
See TracWiki
for help on using the wiki.